1
lm902 2014-04-28 09:12:21 +08:00 1
既然要虚拟Windows 宿主装2012R2然后开Hyper-V虚拟2008R2即可
|
2
wsgzao 2014-04-28 10:30:18 +08:00 1
参与公司云平台前期和中期建设,后期运维协助专注于VMware的同事,正好可以回答楼主的问题
0.硬件配置 目前生产:Cisco UCS B200 M3 *2 + N5K *2[高可用性考虑,楼主请忽略] 目前测试:IBM x3650 M4和Dell R720[考虑x86性能替代] Raid测试:M4 8块900G 10k硬盘,4+4双Raid10 raid10 900GB 10k dd if=/dev/zero of=/test/test bs=8k count=4000000 32768000000 bytes (33 GB) copied, 95.8954 s, 342 MB/s 32768000000 bytes (33 GB) copied, 94.0705 s, 348 MB/s 32768000000 bytes (33 GB) copied, 91.4801 s, 358 MB/s raid10 900GB 10k dd if=/test/test of=/dev/null bs=8k 32768000000 bytes (33 GB) copied, 83.0017 s, 395 MB/s 32768000000 bytes (33 GB) copied, 85.6503 s, 383 MB/s 32768000000 bytes (33 GB) copied, 85.8236 s, 382 MB/s raid10 900GB 10k dd if=/dev/zero of=/test/test bs=32k count=1000000 32768000000 bytes (33 GB) copied, 91.5642 s, 358 MB/s 32768000000 bytes (33 GB) copied, 96.6518 s, 339 MB/s 32768000000 bytes (33 GB) copied, 93.4341 s, 351 MB/s raid10 900GB 10k dd if=/test/test of=/dev/null bs=32k 32768000000 bytes (33 GB) copied, 84.6419 s, 387 MB/s 32768000000 bytes (33 GB) copied, 84.7011 s, 387 MB/s 32768000000 bytes (33 GB) copied, 86.7905 s, 378 MB/s 读取测试均清除缓存,写入测试分首次,清缓存第2次,覆盖第3次 1.背景简述 因为是甲方,配合国家项目发展考虑,采用乙方提供的KVM解决方案,但经过一次重大的未知原因事故后,从成熟性考虑采用VMware的为主要解决方案,KVM的存在也就为了某些原因。 2.回答楼主问题 乙方的实力已经很强,但在KVM实际合作项目中仍显技术不足,如果团队实力不强,生产运维要求较高,非常不建议把人力财力投入在开源虚拟化项目中,如果规模大从成本考虑也就只能硬着头皮上了。还有上述问题中遇到的问题在实际配置中均未有异常,请楼主检查Raid配置,是否带电池支持Cache,是否开启VT支持,部署新版VMware因为有质的提升,版本如下 VMware-VMvisor-Installer-5.5.0.update01-1623387.x86_64.iso VMware-VIMSetup-all-5.5.0-1623099-20140201-update01.iso |
3
wsgzao 2014-04-28 10:38:17 +08:00
最后补充一点,任何技术不存在最好,只有根据当前和未来的业务需求被动选择或者自主研发or二次开发,适合自己的才是最好的
|